First Alert K5309-5V2 Manual do Utilizador Página 42

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 64
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 41
42
0DLQWDLQLQJ<RXU6\VWHP
Taking Care of
Your System
The components of your security system are designed to be as
maintenance-free as possible. However, to make sure that your system
is in reliable working condition, do the following:
1. Test your system weekly
.
2. Test your system after any alarm occurs.
Silencing Low
Battery Warning
Tones at the
Keypad
You can silence the keypads warning tones by pressing the OFF key,
but the keypad's low battery message display will remain on as a
reminder that you have a low battery condition in one or more of your
wireless sensors. When you replace the weak battery with a fresh one,
the sensor sends a "good battery" signal to the control as soon as the
sensor is activated (opening/closing of door, window, etc.), causing the
low battery display to turn off. If the sensor is not activated, the display
will automatically clear within approximately 1 hour.
Replacing
Batteries in
Wireless Sensors
Wireless sensors
may not have
been used in your
security system
IMPORTANT:
Use only batteries
recommended by
your installer as
replacement.
Each wireless sensor in your system has a 9-volt or 3-volt battery. The
system detects a low battery in wireless sensors, including smoke
detectors, the personal emergency transmitter, and the portable
wireless keypad and displays a low battery message*. (A low battery in
a portable wireless keypad is detected as soon as one of its keys is
pressed, and displayed as 00.). Battery-operated smoke detectors with
a low battery also emit a single "chirp" sound approximately once
every 2030 seconds.
Alkaline batteries provide a minimum of 1 year of operation, and in
most units and applications, provide 24 years of service. 3-volt lithium
batteries provide up to 4 or more years of operation. Actual battery life
will depend on the environment in which the sensor is used, the
number of signals that the transmitter in the sensor has had to send,
and the specific type of sensor. Factors such as humidity, high or low
temperatures or large swings in temperature, may all lead to the
reduction of actual battery life in an installation.
*
The low battery message comes on as a warning that battery replacement
in indicated sensor(s) is due within 30 days. In the meantime, a sensor
causing a low battery indication is still fully operational.
Routine Care
Treat the components of your security system as you would any other
electrical equipment. Do not slam sensor-protected doors or windows.
Keep dust from accumulating on the keypad and all protective
sensors, particularly on motion sensors and smoke detectors.
The keypad and sensors should be cleaned carefully with a dry soft
cloth. Do not spray water or any other fluid on the units.
Vista de página 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 63 64

Comentários a estes Manuais

Sem comentários

ResMed Positive Airway Pressure Device VPAP IV manuales

Manuales del propietario y guías del usuario para Sensores ResMed Positive Airway Pressure Device VPAP IV.
Ofrecemos 1 manuales en pdf ResMed Positive Airway Pressure Device VPAP IV para descargar gratis por tipos de documentos: Manual de usuario






Más productos y manuales para Sensores ResMed

Modelos Tipo de documento
Disposable Masks and Circuits Manual de usuario   ResMed Disposable Masks and Circuits User Manual, 2 paginas
Full Face Mask Mirage Quattro Manual de usuario   ResMed Full Face Mask Mirage Quattro User Manual [en] [de] [fr] [it] , 14 paginas
Positive AirwAy Pressure Device S8 Auto 25 Manual de usuario   ResMed Positive AirwAy Pressure Device S8 Auto 25 User Manual, 23 paginas
Positive AirwAy Pressure Device S8 Series II Manual de usuario   ResMed Positive AirwAy Pressure Device S8 Series II User Manual [en] , 22 paginas
Full Face Mask Mirage Liberty Manual de usuario   ResMed Full Face Mask Mirage Liberty User Manual, 14 paginas
Nasal Pillows System Mirage Swift II Manual de usuario   ResMed Nasal Pillows System Mirage Swift II User Manual, 14 paginas
Mirage Quattro 61836/2 Manual de usuario       ResMed Mirage Quattro 61836/2 User Manual [en] , 86 paginas
Ventilator Mask System Sullivan Mirage Manual de usuario      ResMed Ventilator Mask System Sullivan Mirage User Manual, 4 paginas
Positive Airway Pressure Device S8 Manual de usuario   ResMed Positive Airway Pressure Device S8 User Manual [ru] , 20 paginas
Nasal Pillows System Swift LT Manual de usuario   ResMed Nasal Pillows System Swift LT User Manual, 9 paginas
Silent Papillon MAP Series Manual de usuario      ResMed Silent Papillon MAP Series User Manual, 33 paginas
Non-Vented Full Face Mask Mirage Series 2 Manual de usuario       ResMed Non-Vented Full Face Mask Mirage Series 2 User Manual [en] , 44 paginas
Non-Vented Full Face Mask Ultra Mirage Manual de usuario       ResMed Non-Vented Full Face Mask Ultra Mirage User Manual, 74 paginas
Positive Airway Pressure Device S8 Escape II Manual de usuario     ResMed Positive Airway Pressure Device S8 Escape II User Manual, 80 paginas
Nasal Mask Mirage Kidsta Manual de usuario   ResMed Nasal Mask Mirage Kidsta User Manual, 8 paginas
Compact Bilevel Device VPAP Auto Manual de usuario   ResMed Compact Bilevel Device VPAP Auto User Manual, 8 paginas
Non-Vented Full Face Mask Hospital Mask Manual de usuario   ResMed Non-Vented Full Face Mask Hospital Mask User Manual, 12 paginas